Supporting vehicle authorisation through fire safety expertise

Customer: Scheuchzer SA, Switzerland
Project tasks
- Fire safety concept
- Independent expert assessment report
Our approach
The Grizzly 108E, developed by Scheuchzer, is a hybrid rail grinding train designed for preventive and corrective maintenance of rails and switches. The vehicle can operate on either electric or diesel power and is primarily intended for the Swiss railway network.
Vehicle authorisation required a systematic assessment of fire safety risks and documented evidence of compliance with the applicable standards, including EN 14033 and EN 45545-2. Based on operating category 1 and design category N, Hazard Level 1 (HL1) applies to components and assemblies requiring compliance verification.
PROSE developed a comprehensive fire safety concept addressing the vehicle’s specific fire risks and defining appropriate protective measures.
We analysed all relevant areas of the vehicle, including the driver’s cabs, staff accommodation, technical and storage compartments, engine and generator areas, and power supply systems.
The technical and organisational fire protection measures included:
- Audible and visual fire alarms
- Fire suppression systems for the engine compartment
- Generator, transformer and electrical cabinets
- Temperature monitoring and portable fire extinguishers
- Emergency escape routes and exits
- Cleaning, maintenance, staff training and emergency drills
An independent expert assessed the fire safety concept against the applicable standards and carried out a vehicle inspection in Bussigny. The findings were documented in an expert assessment report.
Customer benefit
Scheuchzer benefits from PROSE’s independent railway engineering expertise and our ability to translate complex fire safety requirements into practical, vehicle-specific solutions.
By considering the vehicle as a whole, including its technical systems, operating conditions and organisational measures, we provide a systematic and traceable basis for demonstrating fire safety compliance.
Combined with the independent expert assessment, this gives Scheuchzer reliable technical evidence and a clear foundation for discussions with authorisation authorities, supporting the Grizzly 108E’s approval process.